Alphacool 15376, Reservoar, Polyoksymetylen (POM), Sort, Alphacool DC-LT, 62 mm, 80 mm
FBAC4895-B52C-4E03-B099-A6A8F8B8017B Created with sketchtool. 706D6907-81E1-46A2-B8F9-7B702A1EF2C7 Created with sketchtool. 6A870209-E7F5-44F5-A66F-09E20C85A0DC Created with sketchtool. 0BB04D6C-A9AB-4913-BF4F-5A23954E68E1 Created with sketchtool. 501E26C7-66C1-4DAA-B740-6CFAF55A1B39 Created with sketchtool. C105F7D3-D5EE-43C9-9EE8-05CC42B296D4 Created with sketchtool. D94689D8-7CBB-41C8-AC06-F79D81FF82D5 Created with sketchtool. DA4C7ED9-2512-4D52-94F0-92800F2A6E04 Created with sketchtool. 42E133FD-828F-4CF4-A0BF-560014487A57 Created with sketchtool. F52D9745-4BFD-4506-BEEF-630FD09EF2D9 Created with sketchtool.
Lager
På lager, bestill innen kl. 12:00 så sender vi det samme dag (hverdager). Mere info

Frakt 75,00 - Bring - Hentes på Posten.

Se alle alternativer
Bring - Hentes på Posten75,00
Bring - Fleksibel hjemlevering - Levering til døren (om kvelden i større byer)125,00

Lagerkampanje

Det er 1 på lager

Den aktuelle pris gælder kun så længe lokalt lager haves

NOK 861,55
eksklusiv MVA 689,24
Totalt inkl. frakt 936,55
The Alphacool ES 2U Reservoir is a development for the Enterprise Solution series. It has an integrated pump top for the powerful DDC pump and offers many connection and mounting options. The combination of all these features provides a perfect solution for 2U server racks and workstations.

Extensive connection options
The ES 2U Reservoir has a total of 10 inputs and one output. All connections use a G1/4" thread. There are 2 inputs on each side and on top. Using the top inputs allows you to fill the reservoir perfectly. One inlet is used to fill in the liquid while the second inlet is used to allow the air to escape during filling. Thanks to the extensive connection possibilities there are various options to position the expansion tank in a server rack.

Mounting Options Directly on the Radiator
Ideally, the ES 2U expansion tank is mounted directly on the radiator. For this purpose, three mounting frames and a double nipple fitting are included in the package. The double nipple is used as a direct connection with an Alphacool NexXxoX radiator of the X-Flow series. The reservoir is then attached directly to the radiator using the enclosed mounting brackets. The Alphacool NexXxoS X-Flow radiators naturally have suitable mounting holes for this. This type of mounting makes it possible to position the radiator and reservoir either next to each other or offset in front of the radiator. The corresponding options are listed in detail in the instructions.

Further Mounting Options and Pump Installation
If the ES 2U reservoir is not to be mounted directly on the radiator, it can of course be fastened to any part of the case using the Velcro sheet provided. In this case, one part of the Velcro fastener is stuck to the bottom of the reservoir and the other part to any place in the server rack. To install the pump into the pump top only 4 screws and an O-ring are needed. The O-ring is placed on the reservoir, the pump is put on and fixed with four screws. The entire Alphacool ES Reservoir 2U is then ready for use.

The Alphacool ES 2U Reservoir - DDC version is an extremely compact reservoir especially for 2U server racks with extensive connection and mounting options.