CyberPower Switched ATS PDU44005 - Strømfordelerenhet (kan monteres i rack) - AC 200-240 V - enkeltfase - serial, Ethernet - inngang: 2 x IEC 60320 C20 - utgangskontakter: 10 (8 x IEC 60320 C13, 2 x IEC 60320 C19) - 1U - 3.05 m kabel - svart
FBAC4895-B52C-4E03-B099-A6A8F8B8017B Created with sketchtool. 706D6907-81E1-46A2-B8F9-7B702A1EF2C7 Created with sketchtool. 6A870209-E7F5-44F5-A66F-09E20C85A0DC Created with sketchtool. 0BB04D6C-A9AB-4913-BF4F-5A23954E68E1 Created with sketchtool. 501E26C7-66C1-4DAA-B740-6CFAF55A1B39 Created with sketchtool. C105F7D3-D5EE-43C9-9EE8-05CC42B296D4 Created with sketchtool. D94689D8-7CBB-41C8-AC06-F79D81FF82D5 Created with sketchtool. DA4C7ED9-2512-4D52-94F0-92800F2A6E04 Created with sketchtool. 42E133FD-828F-4CF4-A0BF-560014487A57 Created with sketchtool. F52D9745-4BFD-4506-BEEF-630FD09EF2D9 Created with sketchtool.
Lager
På lager, bestill innen kl. 12:00 så sender vi det samme dag (hverdager). Mere info

Frakt 25,00 med Bring - Hjemlevering - Levering til døren på hverdager

Se alle alternativer
Bring - Hjemlevering - Levering til døren på hverdager mellom 08:00-16:0025,00
Bring - Fleksibel hjemlevering - Levering til døren (om kvelden i større byer)125,00

Lagerkampanje

Det er 7 på lager

Den aktuelle pris gælder kun så længe lokalt lager haves

NOK 7.642,00
eksklusiv MVA 6.113,60
Totalt inkl. frakt 7.667,00
CyberPower PDU44005 provides output from a UPS unit, generator, or utility power to multiple connected devices in IT environments. Dual power cords can be plugged into separate power sources to provide redundancy to single-corded connected equipment. If the selected power source exceeds the desired thresholds or fails, the ATS PDU will automatically switch to the other power source to ensure continuous operation. The unit supports remote individual outlet control over the network, allowing administrators to turn on/off connected devices from any location.

The product is built-in with hot-swappable Ethernet module, which can work with PowerPanel® Power Management Software and power management web interface for real-time remote monitoring and configuration. The digital LCD display is also color configurable, allowing users to easily maintain and monitor the ATS PDU. Users can change LCD’s colors to easily categorize devices between multiple machines in server room and IT environments. Event logging via a web browser or network connection allows users to review the history of power conditions. When specified power events occur, automatic event notifications will be sent via email, SMS text, or SNMP trap to designated users so that they can take immediate actions. The USB port also supports easy firmware upgrade. Moreover, the featured RJ45 port enables the connection of the optional environmental sensor (ENVIROSENSOR), which can provide real-time temperature and humidity monitoring in an IT center.