APC Rack Automatic Transfer Switch AP4421 - Redundant switch (kan monteres i rack) - AC 230 V - Ethernet 10/100, RS-232, USB - utgangskontakter: 12 - 1U - svart - for P/N: SMTL1000RMI2UC, SMX1000C, SMX1500RM2UC, SMX1500RM2UCNC, SMX750C, SMX750CNC
Kjøp julegaver trygt nå 🎁 90 dagers returrett*
FBAC4895-B52C-4E03-B099-A6A8F8B8017B Created with sketchtool. 706D6907-81E1-46A2-B8F9-7B702A1EF2C7 Created with sketchtool. 6A870209-E7F5-44F5-A66F-09E20C85A0DC Created with sketchtool. 0BB04D6C-A9AB-4913-BF4F-5A23954E68E1 Created with sketchtool. 501E26C7-66C1-4DAA-B740-6CFAF55A1B39 Created with sketchtool. C105F7D3-D5EE-43C9-9EE8-05CC42B296D4 Created with sketchtool. D94689D8-7CBB-41C8-AC06-F79D81FF82D5 Created with sketchtool. DA4C7ED9-2512-4D52-94F0-92800F2A6E04 Created with sketchtool. 42E133FD-828F-4CF4-A0BF-560014487A57 Created with sketchtool. F52D9745-4BFD-4506-BEEF-630FD09EF2D9 Created with sketchtool.
Ikke på lager
Varen er ikke på lager.

Frakt 25,00 med Bring - Hjemlevering - Levering til døren på hverdager

Se alle alternativer
Bring - Hjemlevering - Levering til døren på hverdager mellom 08:00-16:0025,00
Bring - Fleksibel hjemlevering - Levering til døren (om kvelden i større byer)125,00

Utsolgt

Varen er ikke på lager.

NOK 18.780,00
eksklusiv MVA 15.024,00
Totalt inkl. frakt 18.805,00
Gi meg beskjed når varen er på lager igjen.
The APC Rack Automatic Transfer Switch (ATS) is a high availability switch that provides redundant power to connected equipment and has two input power cords, one for each AC source. The output configuration is (12) IEC 60320 C13 The Rack ATS supplies power to the connected load from a primary AC source. If that primary source becomes unavailable, the Rack ATS automatically transfers loads to the secondary source. The transfer time from one source to the other is seamless to the connected equipment, as the switching occurs safely between the two input sources regardless of any phase differences. The units have built-in network connectivity, which allows for remote management through Web, SNMP, SHH, Telnet, or StruxureWare Data Center Expert. With multiple outlets, several devices can be plugged directly into the Rack ATS without the need for an additional Rack PDU. Current monitoring and alarms help prevent downtime to the equipment by providing aggregate current measurements and warnings when power consumption draws near the maximum rating of the Rack ATS. Built-in network and local interfaces allow for custom configuration settings for added flexibility.